U-Value Calculator for Extensions

Work out the U-value of a wall, roof or floor build-up in about two minutes, and see whether it meets the Building Regulations limit for a new extension in England.

  • Free to use
  • Headline result with no sign-up
  • Based on Approved Document L, Table 4.2
  • Rules last checked 11th November 2026

Step 1 of 2

What are you building?

We load a typical build-up for this element, which you can then change.
Both are new fabric elements in an existing home and use the same limits.

What U-value does an extension need?

In England, new walls, roofs and floors in an existing home, including extensions and conversions, should meet the limiting U-values in Table 4.2 of Approved Document L, Volume 1: 0.18 W/m²K for walls, 0.15 W/m²K for roofs and 0.18 W/m²K for floors. Windows and doors should be 1.4 W/m²K or better, and rooflights 2.2 W/m²K. A lower U-value means less heat escapes. This calculator adds up the resistance of each layer you enter and compares the result with the limit for that element.

How to use this calculator

  1. Choose the element: an external wall, a pitched roof, a flat roof or a ground floor. We load a typical build-up for it.
  2. Edit the layers from the inside out. Pick a material, enter its thickness in millimetres and, if you have the datasheet, its thermal conductivity (λ).
  3. Press See my result. Your U-value and whether it meets the limit show straight away for free. Add your details to unlock the layer-by-layer breakdown, the extra insulation you need and a free planning report.

How a U-value is worked out

Each layer resists heat flow. Its thermal resistance (R) is its thickness in metres divided by its thermal conductivity (λ). The total resistance is the sum of every layer plus the inside and outside surface resistances, and the U-value is 1 divided by that total:

U = 1 ÷ (Rsi + R1 + R2 + … + Rse)

We use the standard surface resistances for each direction of heat flow: 0.13 inside and 0.04 outside for walls, 0.10 and 0.04 for roofs, and 0.17 and 0.04 for floors. A small unventilated cavity is given a resistance of 0.18 m²K/W.

Typical thermal conductivities

MaterialTypical λ (W/mK)
PIR insulation board0.022
Phenolic insulation board0.020
Mineral wool cavity batt0.035
Mineral wool loft roll0.044
Aircrete block0.15
Brick outer leaf0.77
Dense concrete block1.13

These are typical figures for comparison only. Products vary, so use the declared value on your product's datasheet wherever you can.

For more help, read our guides to householder planning applications and lawful development certificates. Planning the size of your extension? Try our permitted development rear extension calculator or loft conversion volume calculator.

Assumptions and limits

  • It covers England. Wales, Scotland and Northern Ireland set their own limits.
  • It treats each layer as continuous. Timber studs, joists, rafters and wall ties form thermal bridges that usually make the real U-value a little worse, so leave some headroom below the limit.
  • Ground floors are treated as a plain build-up. The ground itself adds resistance, so a full calculation to BS EN ISO 13370 often gives a lower (better) U-value than shown here.
  • For roofs, layers outside a ventilated gap, such as tiles and battens, are left out, as they add almost nothing.
  • Building Control will normally ask for a U-value calculation from the insulation manufacturer or a qualified assessor. Use this tool to check a design before you get one.
  • A 2026 edition of Approved Document L takes effect on 24 March 2027. It keeps the same limits for new walls, roofs and floors in existing homes.

Frequently asked questions

What U-value does a wall need for an extension?

0.18 W/m²K or better, under Table 4.2 of Approved Document L, Volume 1. For a cavity wall this usually means around 100 mm of PIR board or 150 mm of mineral wool in the cavity, with an aircrete inner leaf.

What U-value does a flat roof need?

0.15 W/m²K or better. The same limit applies to pitched roofs. A warm deck flat roof usually needs around 140 to 150 mm of PIR board above the deck.

Is a lower U-value better?

Yes. The U-value is the rate heat passes through one square metre of the element for each degree of temperature difference, so a lower figure means less heat lost and lower heating bills.

Do the limits apply to a loft or garage conversion?

Yes. Walls, roofs and floors that are newly built or newly insulated as part of a conversion are new fabric elements and should meet the same Table 4.2 limits. Renovating an existing element that you are keeping uses different, less strict values.

Can my extension go over the limit if the rest is better?

Sometimes. Approved Document L allows a trade-off where you show, by calculation, that the extension as a whole performs no worse than one built to the standard. This normally needs a SAP assessor.

Do I have to give my details to use the calculator?

No. Your U-value and whether it meets the limit are free with no sign-up. Your details are only needed for the layer-by-layer breakdown, the extra insulation figures and a free planning report from our team.

Last checked 11th November 2026. This tool gives a guide only, based on Approved Document L, Volume 1 (2021 edition incorporating 2023 amendments). It is not a formal U-value calculation, and Building Control has the final say.