The nationally described space standard sets the smallest gross internal floor area and built-in storage a new home should have in England, based on its number of bedrooms, bedspaces and storeys. A 2 bedroom, 4 person flat on one level needs at least 70 m², for example. This calculator looks up your minimum, compares it with your design and checks the bedroom, storage and ceiling height rules too.
The standard is set out in Technical housing standards: nationally described space standard (March 2015, with notes added on 19 May 2016). In plain English, it requires that:
It is a planning standard, not a building regulation. Your council can only require it if its Local Plan refers to it, according to the government's housing optional technical standards guidance, and the council checks compliance. Some councils add their own design policies on top, so check your Local Plan.
There is one case where it applies everywhere in England. Under article 3(9A) of the General Permitted Development Order 2015, permitted development rights do not allow any new home with a gross internal floor area under 37 m², or any new home that does not meet the nationally described space standard. That covers homes made by converting offices, shops or agricultural buildings under permitted development.
For more on getting a scheme through planning, read our guides to pre-application advice, planning drawings and measured surveys. You can also work out your fee with our planning application fee calculator.
| Bedrooms | Bedspaces | 1 storey | 2 storey | 3 storey | Storage |
|---|
Source: Table 1 of the nationally described space standard. A 1 bedroom, 1 person home with a shower room instead of a bathroom can be 37 m².
39 m² for a 1 bedroom, 1 person home, or 37 m² if it has a shower room instead of a bathroom. A 1 bedroom, 2 person flat on one level needs 50 m², and 58 m² over two storeys.
Under the nationally described space standard, which applies in England, a single bedroom must be at least 7.5 m² and 2.15 m wide, and a double or twin at least 11.5 m². One double must be at least 2.75 m wide and any other at least 2.55 m wide.
They are a planning standard, not a building regulation. They apply where your council's Local Plan has adopted them, and to every new home created under permitted development in England.
It is the total floor space measured between the internal faces of the outside walls. It includes internal walls, structure, cupboards, ducts, stairs and the void over stairs. Areas under 1.5 m headroom are left out unless used for storage.
If the flats are created under permitted development, yes, by law. If you apply for planning permission, it depends on whether your council's Local Plan has adopted the standard.
No. Your headline result, including your minimum floor area and whether you meet it, is free with no sign-up. Your details are only needed for the full breakdown and a free planning report from our team.
Last checked 24th November 2026. This tool gives a guide only, based on the rules published at the date above. It is not professional advice, and your council has the final say.
Sign up to receive news, offers, and advice to help your project achieve better outcomes.